翻訳と辞書
Words near each other
・ Standard Parking
・ Standard part function
・ Standard penetration test
・ Standard Performance Evaluation Corporation
・ Standard person
・ Standard pistol
・ Standard Plaza
・ Standard Point Location Code
・ Standard port
・ Standard Portable Intermediate Representation
・ Standard probability space
・ Standard Project Hurricane
・ Standard Publishing
・ Standard rack
・ Standard Radio & Telefon AB
Standard RAID levels
・ Standard rate turn
・ Standard Recording Company
・ Standard Records
・ Standard Reference Method
・ Standard Register Industrial
・ Standard Reinsurance Agreement
・ Standard Romanization (Cantonese)
・ Standard RPG System
・ Standard ruler
・ Standard Sanitary Manufacturing Company
・ Standard scale
・ Standard Schaefer
・ Standard Schedules Information Manual
・ Standard Schnauzer


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Standard RAID levels : ウィキペディア英語版
Standard RAID levels

In computer storage, the standard RAID levels comprise a basic set of RAID configurations that employ the techniques of striping, mirroring, or parity to create large reliable data stores from multiple general-purpose computer hard disk drives (HDDs). The most common types are RAID 0 (striping), RAID 1 and its variants (mirroring), RAID 5 (distributed parity), and RAID 6 (dual parity). RAID levels and their associated data formats are standardized by the Storage Networking Industry Association (SNIA) in the Common RAID Disk Drive Format (DDF) standard.
== RAID 0 ==

RAID 0 (also known as a ''stripe set'' or ''striped volume'') splits ("stripes") data evenly across two or more disks, without parity information, redundancy, or fault tolerance. Since RAID 0 provides no fault tolerance or redundancy, the failure of one drive will cause the entire array to fail; as a result of having data striped across all disks, the failure will result in total data loss. This configuration is typically implemented having speed as the intended goal.〔(【引用サイトリンク】 RAID 0 Data Recovery )〕〔(【引用サイトリンク】 Understanding RAID )〕 RAID 0 is normally used to increase performance, although it can also be used as a way to create a large logical volume out of two or more physical disks.
A RAID 0 setup can be created with disks of differing sizes, but the storage space added to the array by each disk is limited to the size of the smallest disk. For example, if a 120 GB disk is striped together with a 320 GB disk, the size of the array will be 120 GB × 2 = 240 GB.
The diagram in this section shows how the data is distributed into A stripes on two disks, with A1:A2 as the first stripe, A3:A4 as the second one, etc. Once the stripe size is defined during the creation of a RAID 0 array, it needs to be maintained at all times. Since the stripes are accessed in parallel, an -drive RAID 0 array appears as a single large disk with a data rate times higher than the single-disk rate.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Standard RAID levels」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.